Question: After clicking the reset button, the device has no action, but the software and the W-axis coordinate on the touch screen keep jumping
Answer: Check if the device enable switch is turned off
Check if the W pulse line is connected correctly/broken
Check if the W-axis motor wire is connected correctly/broken